Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Environ Manage ; 328: 116910, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36495826

RESUMO

Urban air pollution is a global concern impairing citizens' health, thus monitoring is a pressing need for city managers. City-wide networks for air pollution monitoring based on low-cost sensors are promising to provide real-time data with detail and scale never before possible. However, they still present limitations preventing their ubiquitous use. Thus, this study aimed to perform a post-deployment validation and calibration based on two step methods for ozone low-cost sensor of a city-wide network for air pollution and meteorology monitoring using low-cost sensors focusing on the main challenges. Four of the 23 data collection units (DCUs) of the UrbanSense network installed in Porto city (Portugal) with low-cost sensors for particulate matter (PM), carbon monoxide (CO), ozone (O3), and meteorological variables (temperature, relative humidity, luminosity, precipitation, and wind speed and direction) were evaluated. This study identified post-deployment challenges related to their validation and calibration. The preliminary validation showed that PM, CO and precipitation sensors recorded only unreliable data, and other sensors (wind speed and direction) very few data. A multi-step calibration strategy was implemented: inter-DCU calibration (1st step, for O3, temperature and relative humidity) and calibration with a reference-grade instrument (2nd step, for O3). In the 1st step, multivariate linear regression (MLR) resulted in models with better performance than non-linear models such as artificial neural networks (errors almost zero and R2 > 0.80). In the 2nd step, the calibration models using non-linear machine learning boosting algorithms, namely Stochastic Gradient Boosting Regressor (both with the default and post-tuning hyper-parameters), performed better than artificial neural networks and linear regression approaches. The calibrated O3 data resulted in a marginal improvement from the raw data, with error values close to zero, with low predictability (R2 ∼ 0.32). The lessons learned with the present study evidenced the need to redesign the calibration strategy. Thus, a novel multi-step calibration strategy is proposed, based on two steps (pre and post-deployment calibration). When performed cyclically and continuously, this strategy reduces the need for reference instruments, while probably minimising data drifts over time. More experimental campaigns are needed to collect more data and further improve calibration models.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Ozônio , Poluentes Atmosféricos/análise , Calibragem , Monitoramento Ambiental/métodos , Poluição do Ar/análise , Material Particulado/análise , Coleta de Dados
2.
Sci Total Environ ; 727: 138385, 2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32498203

RESUMO

The use of low-cost sensor technology to monitor air pollution has made remarkable strides in the last decade. The development of low-cost devices to monitor air quality in indoor environments can be used to understand the behaviour of indoor air pollutants and potentially impact on the reduction of related health impacts. These user-friendly devices are portable, require low-maintenance, and can enable near real-time, continuous monitoring. They can also contribute to citizen science projects and community-driven science. However, low-cost sensors have often been associated with design compromises that hamper data reliability. Moreover, with the rapidly increasing number of studies, projects, and grey literature based on low-cost sensors, information got scattered. Intending to identify and review scientifically validated literature on this topic, this study critically summarizes the recent research pertinent to the development of indoor air quality monitoring devices using low-cost sensors. The method employed for this review was a thorough search of three scientific databases, namely: ScienceDirect, IEEE, and Scopus. A total of 891 titles published since 2012 were found and scanned for relevance. Finally, 41 research articles consisting of 35 unique device development projects were reviewed with a particular emphasis on device development: calibration and performance of sensors, the processor used, data storage and communication, and the availability of real-time remote access of sensor data. The most prominent finding of the study showed a lack of studies consisting of sensor performance as only 16 out of 35 projects performed calibration/validation of sensors. An even fewer number of studies conducted these tests with a reference instrument. Hence, a need for more studies with calibration, credible validation, and standardization of sensor performance and assessment is recommended for subsequent research.

3.
Environ Pollut ; 258: 113745, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31855678

RESUMO

Active transportation (walking or cycling) as a substitute for car trips still represents a small percentage of all daily travels in many European cities. This study aimed to estimate the health and economic co-benefits for the adult population of modal shift from driving to active travel in urban environments. Three scenarios were modelled for the case study, the city of Porto, Portugal, by comparing travel patterns of 2013 to hypothetical scenarios of modal shifts from driving to active transport, namely: i) SC1 - conservative scenario, with a change of 5% from driving to cycling and 10% from driving to walking; ii) SC2 - moderate scenario, with a shift of 10% and 15%, respectively; and iii) SC3 - optimistic scenario, with a shift of 15% and 20%, respectively. The mortality risk reduction for five health outcomes (colon and breast cancers, diabetes, ischemic heart disease, cerebrovascular disease) was assessed, including an estimation of traffic injury and air pollution exposure risks. Results were presented in Disability-Adjusted Life Years (DALYs) avoided. Economic valuation for each scenario was performed using a Willingness-to-Pay approach for morbimortality and a Cost of Illness approach for 2013 hospitalizations and work absenteeism. Significant health benefits were found in all modelled scenarios, ranging from 1657 (16%) to 2881 (28%) DALYs avoided. Total costs averted ranged from €3894 to €6769 million through the scenarios. Cardio and cerebrovascular diseases mortality presented the largest benefit, accounting for about 3/4 of all avoidable DALYs in all scenarios. Reductions in CO2 and PM10 emissions were calculated, showing a decrease from 31.6 to 73.7 kt of CO2 and 7 to 16 t for PM10, respectively. A modal shift towards active transportation could lead to significant health and economic benefits, indicating that the evaluation of health impacts should be included in the analysis of active transport interventions.


Assuntos
Poluição do Ar , Comportamentos Relacionados com a Saúde , Mortalidade , Meios de Transporte/métodos , Adulto , Condução de Veículo , Ciclismo , Transporte Biológico Ativo , Cidades , Humanos , Portugal , Comportamento de Redução do Risco , Caminhada
4.
Environ Res ; 176: 108534, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31220738

RESUMO

Poor indoor air quality can adversely affect children's health, comfort and school performance, but existing literature on quantifying indoor air pollutants (IAP) determinants' in nursery and primary schools is limited. Following previous studies, this study mainly aimed to quantify determinants of selected IAP, in nursery and primary schools from both urban and rural sites, accounting for seasonal variations. In 101 indoor microenvironments (classrooms, bedrooms and canteens) from 25 nursery and primary schools, CO2, CO, HCOH, NO2, O3, total volatile organic compounds, PM1, PM2.5, PM10, total suspended particles (TSP), and meteorological/comfort parameters were continuously sampled (occupancy and background levels), from at least 24 h to 9 consecutive days (not simultaneously) in each studied room; in some cases weekend was also considered. Children faced thermal discomfort and inadequate humidity, respectively in 60.1% and 44.1% of the studied classrooms. They were also exposed to high levels of IAP, namely PM2.5 and CO2 respectively in 69.0% and 41.3% of the studied classrooms, mostly in urban sites, depending on season and on occupancy and activity patterns (different amongst age groups). As PM2.5 and CO2 were the major concerning IAP, multivariate linear regression models were built to quantify (explained variability and relative importance) their main determinants, in both occupancy and non-occupancy (background) periods. Models for occupancy periods showed higher explained variability (R2 = 0.64, 0.57 and 0.47, respectively, for CO2, PM2.5 and PM10) than for non-occupancy. Besides background concentrations (43.5% of relative importance), relative humidity (21.1%), flooring material (17.0%), heating (6.7%) and age group of the occupants (5.3%), adjusted for season of sampling (6.4%) were predictors in CO2 occupancy model. In the cases of PM2.5 and PM10 occupancy concentrations, besides background concentrations (71.2% and 67.2% of relative importance, respectively for PM2.5 and PM10), type of school management (8.8% and 15.2%) and flooring material (13.9% and 13.9%), adjusted for season of sampling (6.1% and 3.8%), were the main predictors. These findings support the need of mitigation measures to reduce IAP levels, and prevention actions to avoid children's exposure. Reducing the time spent indoors in the same microenvironment by doing more and/or longer breaks, improving ventilation and cleaning actions, and avoiding or making a better maintenance hardwood flooring materials, chalkboard use and VOC emitting materials, are practices that should be implemented and their impacts quantified.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Monitoramento Ambiental , Criança , Humanos , Material Particulado , Instituições Acadêmicas , Ventilação
5.
J Environ Manage ; 235: 62-69, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30677656

RESUMO

Maritime sector is expected to continue growing significantly in line with world trade, however its impacts on environmental, social and human health are not yet fully known. Thus, this study aimed to estimate the external costs of in-port shipping emissions (NOx, SO2, CO2, VOCs and PM2.5) and accomplish a comprehensive eco-efficiency evaluation of four ports in Portugal (Leixões, Setúbal, Sines and Viana do Castelo) during 2013. External costs were based on the external cost factors from BeTa, CAFE and NEEDS projects and from Song (2014). Eco-efficiency evaluation was based on environmental, social and economic criteria. Results showed higher externalities for Sines and Setúbal (2.0E+02 million €), followed by Leixões (1.8E+02 million €), and Viana do Castelo (6.3 million €). NOx, SO2, and PM2.5 were the pollutants with the highest externalities. Sines port showed the best overall eco-efficiency. Although Setúbal port showed higher performance than Viana do Castelo port based on the economic data, when social and environmental aspects were considered the results changed. This shows the importance of performing a more comprehensive analysis using social and environmental indicators. The combination of all these indicators is highly important to support the implementation of policies for the abatement of shipping in-port emissions.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Humanos , Portugal , Navios
6.
Environ Pollut ; 231(Pt 2): 1370-1379, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28917818

RESUMO

In the last few years, ship emissions have attracted growing attention in the scientific community. The main reason is the constant increase of marine emissions over the last twenty years due to the intensification of port traffic. Thus, this study aimed to evaluate ship emissions (PM10, PM2.5, NOx, SO2, CO, CO2, N2O CH4, NMVOC, and HC) through the activity-based methodology in four of the main ports of Portugal (Leixões, Setúbal, Sines and Viana do Castelo) during 2013 and 2014. The analysis was performed according to ship types (bulk carrier, container, general cargo, passenger, Ro-Ro cargo, tanker and others) and operational modes (manoeuvring, hotelling and during cruising). Results indicated that tankers were the largest emitters in two of the four analysed ports. Regarding cruising emissions, container ships were the largest emitters. . CO2, NOx and SO2 estimated emissions represented more than 95% of the cruising and in-port emissions. Results were also compared with the total national emissions reported by the Portuguese Environment Agency, and if the in-port emissions estimated in the present study would have been taken into account to these totals, emissions of NOx and SO2 would increase 15% and 24% in 2013 and 16% and 28% in 2014. Summing up ships seem to be an important source of air pollution, mainly regarding NOx and SO2.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/estatística & dados numéricos , Monitoramento Ambiental , Navios/estatística & dados numéricos , Emissões de Veículos/análise , Poluição do Ar/análise , Portugal
7.
Environ Pollut ; 231(Pt 1): 87-103, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28793241

RESUMO

Several studies tried to estimate atmospheric emissions with origin in the maritime sector, concluding that it contributed to the global anthropogenic emissions through the emission of pollutants that have a strong impact on hu' health and also on climate change. Thus, this paper aimed to review published studies since 2010 that used activity-based methodology to estimate ship emissions, to provide a summary of the available input data. After exclusions, 26 articles were analysed and the main information were scanned and registered, namely technical information about ships, ships activity and movement information, engines, fuels, load and emission factors. The larger part of studies calculating in-port ship emissions concluded that the majority was emitted during hotelling and most of the authors allocating emissions by ship type concluded that containerships were the main pollutant emitters. To obtain technical information about ships the combined use of data from Lloyd's Register of Shipping database with other sources such as port authority's databases, engine manufactures and ship-owners seemed the best approach. The use of AIS data has been growing in recent years and seems to be the best method to report activities and movements of ships. To predict ship powers the Hollenbach (1998) method which estimates propelling power as a function of instantaneous speed based on total resistance and use of load balancing schemes for multi-engine installations seemed to be the best practices for more accurate ship emission estimations. For emission factors improvement, new on-board measurement campaigns or studies should be undertaken. Regardless of the effort that has been performed in the last years to obtain more accurate shipping emission inventories, more precise input data (technical information about ships, engines, load and emission factors) should be obtained to improve the methodology to develop global and universally accepted emission inventories for an effective environmental policy plan.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Navios , Mudança Climática , Navios/normas
9.
Rev Port Pneumol (2006) ; 22(3): 146-50, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26747645

RESUMO

Asthma is the commonest and most important chronic non-infectious disease in childhood and it has become more prevalent in recent years. There is a shortage of studies in relation to early childhood and so, as part of the INAIRCHILD project, this cross-sectional study aimed to assess the prevalence of asthma and its associated risk factors, namely demographic, environmental, psychosocial and clinical factors for infants and preschoolers living in Northern Portugal. Data concerning asthma prevalence were collected through questionnaires based on those from the International Study of Asthma and Allergies in Childhood (ISAAC-derived), the questionnaires were distributed to 1042 children attending the 17 nurseries involved in the INAIRCHILD project (10 in urban and suburban context, and 7 in rural context). The response rate was 48%. Prevalence of asthma based on symptomatology and odds ratio was calculated. Around 52% of the studied children presented at least one of the respiratory symptoms investigated (wheeze, dyspnea and cough) in the absence of upper respiratory infections. The prevalence of asthma was 10.7%, comparable to the figures for Portuguese schoolchildren (6-7 years old) reported by the national Directorate-General of Health, thus showing that an early diagnosis might be possible and helpful for the mitigation of childhood asthma. Environmental context (urban, suburban or rural), gender and family asthma history showed clear associations with asthma prevalence, namely non-rural location, male gender, and having an asthmatic parent were found to be risk factors.


Assuntos
Asma/epidemiologia , Criança , Pré-Escolar , Estudos Transversais , Humanos , Lactente , Portugal/epidemiologia , Prevalência , Fatores de Risco
10.
Environ Pollut ; 208(Pt A): 2-15, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26239833

RESUMO

Indoor air quality in nursery schools is different from other schools and this has been largely ignored, particularly in rural areas. Urban and rural nursery schools have different environmental characteristics whose knowledge needs improvement. Thus, this study aimed to evaluate continuously the concentrations of CO2, CO, NO2, O3, CH2O and total VOC in three rural nursery schools and one urban, being the only one comparing urban and rural nurseries with continuous measurements, thus considering occupation and non-occupation periods. Regarding CO2, urban nursery recorded higher concentrations (739-2328 mg m(-3)) than rural nurseries (653-1078 mg m(-3)). The influence of outdoor air was the main source of CO, NO2 and O3 indoor concentrations. CO and NO2 concentrations were higher in the urban nursery and O3 concentrations were higher in rural ones. CH2O and TVOC concentrations seemed to be related to internal sources, such as furniture and flooring finishing and cleaning products.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Escolas Maternais , Pré-Escolar , Monitoramento Ambiental , Humanos , Lactente , Portugal , População Rural
11.
Environ Res ; 142: 662-70, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26342590

RESUMO

This study, Part II of the larger study "Children's exposure to indoor air in urban nurseries", aimed to: (i) evaluate nursery schools' indoor concentrations of several air pollutants in class and lunch rooms; and (ii) analyse them according to guidelines and references. Indoor continuous measurements were performed, and outdoor concentrations were obtained to determine indoor/outdoor ratios. The influence of outdoor air seemed to be determinant on carbon monoxide (CO), nitrogen dioxide (NO2) and ozone (O3) indoor concentrations. The peak concentrations of formaldehyde and volatile organic compounds (VOC) registered (highest concentrations of 204 and 2320 µg m(-3) respectively), indicated the presence of specific indoor sources of these pollutants, namely materials emitting formaldehyde and products emitting VOC associated to cleaning and children's specific activities (like paints and glues). For formaldehyde, baseline constant concentrations along the day were also found in some of the studied rooms, which enhances the importance of detailing the study of children's short and long-term exposure to this indoor air pollutant. While CO, NO2 and O3 never exceeded the national and international reference values for IAQ and health protection, exceedances were found for formaldehyde and VOC. For this reason, a health risk assessment approach could be interesting for future research to assess children's health risks of exposure to formaldehyde and to VOC concentrations in nursery schools. Changing cleaning schedules and materials emitting formaldehyde, and more efficient ventilation while using products emitting VOC, with the correct amount and distribution of fresh air, would decrease children's exposure.


Assuntos
Poluição do Ar em Ambientes Fechados , Exposição Ambiental , Escolas Maternais , População Urbana , Pré-Escolar , Humanos
12.
J Toxicol Environ Health A ; 78(13-14): 805-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26167747

RESUMO

Lung cancer has been associated with radon concentration even at low levels such as those found in dwellings. This study aimed to (i) determine radon diurnal variations in three nurseries and one primary school in the Bragança district (north of Portugal) and (ii) compare radon concentrations with legislated standards and assess the legislated procedures. Radon was measured in three nurseries and a primary school in a rural area with nongranite soil. Measurements were performed continuously to examine differences between occupation and nonoccupation periods. Indoor temperature and relative humidity were also measured continuously. A great variability was found in radon concentrations between the microenvironments examined. Radon concentrations surpassed by severalfold the recommended guidelines and thresholds, and excessive levels of health concern were sporadically found (361.5-753.5 Bq m(-3)). Thus, it is of importance to perform a national campaign on radon measurements and to reduce exposure.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental , Radônio/análise , Pré-Escolar , Ritmo Circadiano , Humanos , Lactente , Recém-Nascido , Berçários para Lactentes , Portugal , Monitoramento de Radiação , Instituições Acadêmicas
13.
Environ Pollut ; 202: 7-16, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25795175

RESUMO

Studies have been showing strong associations between exposures to indoor particulate matter (PM) and health effects on children. Urban and rural nursery schools have different known environmental and social differences which make their study relevant. Thus, this study aimed to evaluate indoor PM concentrations on different microenvironments of three rural nursery schools and one urban nursery school, being the only study comparing urban and rural nursery schools considering the PM1, PM2.5 and PM10 fractions (measured continuously and in terms of mass). Outdoor PM2.5 and PM10 were also obtained and I/O ratios have been determined. Indoor PM mean concentrations were higher in the urban nursery than in rural ones, which might have been related to traffic emissions. However, I/O ratios allowed concluding that the recorded concentrations depended more significantly of indoor sources. WHO guidelines and Portuguese legislation exceedances for PM2.5 and PM10 were observed mainly in the urban nursery school.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Material Particulado/análise , População Rural , Escolas Maternais , População Urbana , Criança , Pré-Escolar , Monitoramento Ambiental/legislação & jurisprudência , Regulamentação Governamental , Humanos , Masculino , Tamanho da Partícula , Portugal
14.
Environ Res ; 140: 1-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25800634

RESUMO

Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study "Children's exposure to indoor air in urban nurseries", aimed to: i) evaluate nurseries' indoor concentrations of carbon dioxide (CO2), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters-temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO2 concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados , Dióxido de Carbono/análise , Exposição Ambiental , Berçários para Lactentes , População Urbana , Criança , Fidelidade a Diretrizes , Nível de Saúde , Humanos
15.
Environ Res ; 135: 317-32, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25462682

RESUMO

Exposures to a wide spectrum of air pollutants were associated to several effects on children's health. Exposure assessment can be used to establish where and how air pollutants' exposures occur. However, a realistic estimation of children's exposures to air pollution is usually a great ethics challenge, especially for young children, because they cannot intentionally be exposed to contaminants and according to Helsinki declaration, they are not old enough to make a decision on their participation. Additionally, using adult surrogates introduces bias, since time-space-activity patterns are different from those of children. From all the different available approaches for exposure assessment, the microenvironmental (ME) modelling (indirect approach, where personal exposures are estimated or predicted from microenvironment measurements combined with time-activity data) seemed to be the best to assess children's exposure to air pollution as it takes into account the varying levels of pollution to which an individual is exposed during the course of the day, it is faster and less expensive. Thus, this review aimed to explore the use of the ME modelling approach methodology to assess children's exposure to air pollution. To meet this goal, a total of 152 articles, published since 2002, were identified and titles and abstracts were scanned for relevance. After exclusions, 26 articles were fully reviewed and main characteristics were detailed, namely: (i) study design and outcomes, including location, study population, calendar time, pollutants analysed and purpose; and (ii) data collection, including time-activity patterns (methods of collection, record time and key elements) and pollution measurements (microenvironments, methods of collection and duration and time resolution). The reviewed studies were from different parts of the world, confirming the worldwide application, and mostly cross-sectional. Longitudinal studies were also found enhancing the applicability of this approach. The application of this methodology on children is different from that on adults because of data collection, namely the methods used for collecting time-activity patterns must be different and the time-activity patterns are itself different, which leads to select different microenvironments to the data collection of pollutants' concentrations. The most used methods to gather information on time-activity patterns were questionnaires and diaries, and the main microenvironments considered were home and school (indoors and outdoors). Although the ME modelling approach in studies to assess children's exposure to air pollution is highly encouraged, a validation process is needed, due to the uncertainties associated with the application of this approach.


Assuntos
Poluentes Atmosféricos/análise , Meio Ambiente , Exposição Ambiental/análise , Monitoramento Ambiental/métodos , Modelos Biológicos , Criança , Monitoramento Ambiental/estatística & dados numéricos , Humanos , Atividade Motora , Inquéritos e Questionários , Fatores de Tempo
16.
Arq. bras. med. vet. zootec ; 66(5): 1401-1405, Sep-Oct/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-729765

RESUMO

Callithrix jacchus is a neotropical primate adaptable in captivity. Colonies can be easily established in a short time and at low cost compared to other species of larger primates, which are normally used in laboratory. Because they are phylogenetically similar to humans in situations that induce anxiety, these small primates are increasingly being used in research involving the stress response. Wild animals in captivity are subjected to a series of stressful events that depending on the duration and intensity can modify the organic homeostasis. Observed in this study, serious problems occurred with the formation in fetal offspring of Callithrix jacchus kept in an environment with a high degree of stress...


O Callithrix jacchus é um primata neotropical de fácil adaptação em cativeiro. As colônias podem ser facilmente estabelecidas em um curto espaço de tempo e a um custo baixo comparado a outras espécies de primatas maiores, que são normalmente utilizados em laboratório. Por serem filogeneticamente semelhantes aos seres humanos em situações que induzem à ansiedade, esses pequenos primatas estão sendo cada vez mais utilizados em pesquisas que envolvam a resposta ao estresse. Animais silvestres em cativeiro estão submetidos a uma série de eventos estressores, os quais, dependendo da sua duração e intensidade, podem modificar a homeostase orgânica. Observaram-se, neste estudo, graves problemas ocorridos com a formação fetal nas proles de Callithrix jacchus mantidos em ambiente com alto grau de estresse...


Assuntos
Animais , Animais de Laboratório , Callithrix/crescimento & desenvolvimento , Desenvolvimento Fetal , Transtornos de Ansiedade , Homeostase , Hidrocortisona/metabolismo
17.
Arq. bras. med. vet. zootec ; 65(4): 981-988, Aug. 2013. graf, tab
Artigo em Português | LILACS | ID: lil-684451

RESUMO

Foram colhidas amostras de 100 carcaças em um frigorífico exportador, localizado no interior do estado de São Paulo, amostradas ao longo de um ano, por meio do método de esponjas, aplicado na região do peito do animal. As amostras foram colhidas em três pontos, denominados A, B e C, sendo cada carcaça amostrada nos três pontos, localizados nas etapas: pós-sangria (A); pós-esfola (B) e pós-lavagem (C). Foram realizadas pesquisas de Listeria sp., E. coli O157, Salmonella spp. e microrganismos indicadores (Petrifilms® AC, EC e EB). Não foram isolados Listeria ou E. coli O157 em nenhuma das 300 amostras. Salmonella spp. foi isolada em nove, sendo oito no ponto A e uma no ponto B. Para mesófilos, as contagens variaram de 0 a 6,8 log UFC/cm², para coliformes totais, de 0 a 4,57 log UFC/cm², e para E. coli, de 0 a 4,38 log UFC/cm². Diante dos resultados obtidos e em comparação com a literatura, conclui-se que o estabelecimento estudado apresenta qualidade, tanto sanitária (devido às baixas prevalências dos patógenos) quanto higiênica (devido à acentuada diminuição da carga microbiana de indicadores ao longo da linha).


Samples were collected from 100 carcasses in a slaughterhouse exporter, located within the State of São Paulo, sampled over a year through the sponge method, applied to the chest of the animal. Samples were taken at three points, denominated A, B and C, each carcass sampled at three points located in the following steps: after bleeding (A) after skinning (B) and after washing (C). Research was conducted for Listeria sp., E. coli O157, Salmonella spp. and Micro-organism (Petrifilms ® AC, EC and EB). Listeria or E. coli O157 were not isolated in any of the 300 samples. Salmonella spp. was isolated in nine, eight at point A and one at point B. For Mesophiles, scores ranged from 0 to 6.8 log UFC/cm²; for Total coliforms, 0 to 4.57 log UFC/cm² and E. coli from 0 to 4.38 log UFC/cm². With the results obtained and compared with the literature, it is concluded that the establishment in this study has both sanitary quality (due to the low prevalence of pathogens) and hygienic quality (due to the sharp decrease in the microbial load of indicators along the line.


Assuntos
Animais , Bovinos , Conservantes de Alimentos , Carne/análise , Listeria monocytogenes/patogenicidade , Salmonella/patogenicidade , Bovinos/classificação
18.
Environ Sci Pollut Res Int ; 20(8): 5096-105, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23673923

RESUMO

Microalgae culture is still not economically viable and it presents some negative environmental impacts, concerning water, nutrient and energy requirements. In this context, this study aims to review the recent advances on microalgal cultures in wastewaters to enhance their economic viability. We focused on three different culture concepts: (1) suspended cell systems, (2) cell immobilization, and (3) microalgae consortia. Cultures with suspended cells are the most studied. The nutrient removal efficiencies are usually high for wastewaters of different sources. However, biomass harvesting is difficult and a costly process due to the small cell size and lower culture density. On the other hand, the cell immobilization systems showed to be the solution for this problem, having as main limitation the nutrient diffusion from bulk to cells, which results in a reduced nutrient removal efficiency. The consortium between microalgae and bacteria enhances the growth of both microorganisms. This culture concept showed to be a promising technology to improve wastewater treatment, regarding not only nutrient removal but also biomass harvesting by bioflocculation. The aggregation mechanism must be studied in depth to find the process parameters that would lead to an effective and cheap harvesting process.


Assuntos
Microalgas , Águas Residuárias/microbiologia , Poluição do Ar/prevenção & controle , Biocombustíveis , Técnicas de Cultura de Células , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/métodos
19.
Chemosphere ; 90(7): 2051-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23228906

RESUMO

Protecting the health of children and the environment is an essential objective for the health policies of any modern society, being also crucial for a sustainable development, according to the World Health Organization. Evaluating the risk of developing childhood asthma is one of the four priority issues identified by the European Commission, according to the European Union Environment and Health Action Plan. Accordingly, this review aimed to update information concerning the effects of exposure to ozone on childhood asthma, thus helping in the development of strategies for further research. Studies have been demonstrating strong associations between the exposure to ozone and asthma. However, the complexity of exposure patterns, the changes in the vulnerability of children at various stages of development, and the practical limitations of research, lead to a still incomplete understanding of the ozone impact on the health of children. Difficulties on the interpretation of epidemiological studies to evaluate chronic effects are mainly due to an absence of studies designed specifically to address this question and to inherent limitations in characterizing exposure. The more rigorous studies provided new evidences for chronic effects of ozone on small airway function and possibly on asthma, but substantial uncertainties remain.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/estatística & dados numéricos , Asma/epidemiologia , Ozônio/análise , Poluentes Atmosféricos/toxicidade , Poluição do Ar/legislação & jurisprudência , Criança , Estudos Epidemiológicos , Europa (Continente)/epidemiologia , União Europeia , Humanos , Ozônio/toxicidade
20.
Environ Sci Pollut Res Int ; 20(6): 3932-45, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23184127

RESUMO

This study aimed to characterize air pollution and the associated carcinogenic risks of polycyclic aromatic hydrocarbon (PAHs) at an urban site, to identify possible emission sources of PAHs using several statistical methodologies, and to analyze the influence of other air pollutants and meteorological variables on PAH concentrations.The air quality and meteorological data were collected in Oporto, the second largest city of Portugal. Eighteen PAHs (the 16 PAHs considered by United States Environment Protection Agency (USEPA) as priority pollutants, dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were collected daily for 24 h in air (gas phase and in particles) during 40 consecutive days in November and December 2008 by constant low-flow samplers and using polytetrafluoroethylene (PTFE) membrane filters for particulate (PM10 and PM2.5 bound) PAHs and pre-cleaned polyurethane foam plugs for gaseous compounds. The other monitored air pollutants were SO2, PM10, NO2, CO, and O3; the meteorological variables were temperature, relative humidity, wind speed, total precipitation, and solar radiation. Benzo[a]pyrene reached a mean concentration of 2.02 ng m(-3), surpassing the EU annual limit value. The target carcinogenic risks were equal than the health-based guideline level set by USEPA (10(-6)) at the studied site, with the cancer risks of eight PAHs reaching senior levels of 9.98 × 10(-7) in PM10 and 1.06 × 10(-6) in air. The applied statistical methods, correlation matrix, cluster analysis, and principal component analysis, were in agreement in the grouping of the PAHs. The groups were formed according to their chemical structure (number of rings), phase distribution, and emission sources. PAH diagnostic ratios were also calculated to evaluate the main emission sources. Diesel vehicular emissions were the major source of PAHs at the studied site. Besides that source, emissions from residential heating and oil refinery were identified to contribute to PAH levels at the respective area. Additionally, principal component regression indicated that SO2, NO2, PM10, CO, and solar radiation had positive correlation with PAHs concentrations, while O3, temperature, relative humidity, and wind speed were negatively correlated.


Assuntos
Poluição do Ar/análise , Carcinógenos/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Adolescente , Adulto , Idoso , Poluentes Atmosféricos/análise , Testes de Carcinogenicidade , Criança , Pré-Escolar , Cidades , Monitoramento Ambiental/métodos , Humanos , Lactente , Pessoa de Meia-Idade , Portugal , Análise de Componente Principal , Medição de Risco , Fatores de Risco , Dióxido de Enxofre/análise , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS